Hello and welcome to the demonstration
of our sensorless correction

2
00:00:04.097 --> 00:00:06.552
software Phinden, interacting with
µManager.

3
00:00:06.873 --> 00:00:10.950
Our setup is a commercial brightfield
microscope with the Delta 7-10

4
00:00:10.950 --> 00:00:15.147
directly attached to the 10x
objective. It images a blood smear
sample

5
00:00:15.147 --> 00:00:17.065
with an aberration plate on top.

6
00:00:17.346 --> 00:00:21.074
First, you have to open µManager with
your specific camera config file.

7
00:00:30.539 --> 00:00:34.587
Make all settings for your camera,
like the bit depth and exposure time.

8
00:00:38.184 --> 00:00:41.464
Now you can click on live to see the
live stream of your sample.

9
00:00:41.464 --> 00:00:45.518
You can adjust the brightness to get a
better contrast to find aberrated

10
00:00:45.518 --> 00:00:45.856
areas.

11
00:00:47.285 --> 00:00:51.546
The next step is to find the ROI. Draw
a rectangle around the region you

12
00:00:51.546 --> 00:00:55.806
want to have corrected and click on
the blue rectangle below the written

13
00:00:55.806 --> 00:00:59.948
ROI at the µManager screen. Now you
can see the cropped image. You can

14
00:00:59.948 --> 00:01:02.493
close the live view and the inspect
window.

15
00:01:05.199 --> 00:01:09.774
Now open the command line window or
your environment where Python is

16
00:01:09.774 --> 00:01:14.350
installed. Go into Python and type in
from Phinden import * and then

17
00:01:14.350 --> 00:01:15.359
launch_Phinden.

18
00:01:18.338 --> 00:01:22.542
The stream window of Phinden will
open. Click on the drop down menu

19
00:01:22.542 --> 00:01:26.808
where simulation is listed and choose
µManager. Click on snap single

20
00:01:26.808 --> 00:01:31.263
image to get one snap of the cropped
ROI or click start stream to get a

21
00:01:31.263 --> 00:01:31.890
live view.

22
00:01:42.614 --> 00:01:46.573
Now, open correction UI to get the
correction window of Phinden.

23
00:01:46.573 --> 00:01:50.383
You have to choose your working
directory where everything will be

24
00:01:50.383 --> 00:01:54.252
saved. If your Delta is connected,
click on open DPP connection and

25
00:01:54.252 --> 00:01:55.926
choose your calibration file.

26
00:02:09.101 --> 00:02:12.585
On workflow options, you can open
advanced settings to fine-tune the

27
00:02:12.585 --> 00:02:13.149
correction.

28
00:02:25.347 --> 00:02:29.553
If you click on select aberrations a
Zernike tree will open. Here you

29
00:02:29.553 --> 00:02:33.699
can choose for which aberrations it
should look for corrections. Now

30
00:02:33.699 --> 00:02:36.747
everything is ready to go click on get
correction.

31
00:02:44.553 --> 00:02:47.995
It will iterate through all chosen
modes to find the best combination

32
00:02:47.995 --> 00:02:48.793
for your sample.

33
00:03:09.428 --> 00:03:13.214
Once finished, it shows you an image
of the corrected sample and it will

34
00:03:13.214 --> 00:03:15.580
plot all fitting curves for the chosen
modes.

35
00:03:20.504 --> 00:03:23.996
You can toggle now between flatten
surface and apply correction to see

36
00:03:23.996 --> 00:03:24.744
the difference.

37
00:03:30.454 --> 00:03:32.094
Thank you for watching this video.

38
00:03:32.094 --> 00:03:35.937
If you are also interested to get the
best out of your imaging system,

39
00:03:35.937 --> 00:03:37.254
feel free to contact us.

40
00:03:37.254 --> 00:03:40.086
You can find more info on
phaseform.com.